Version 1.0.3
AlphaThird alpha update.
- The dial and fader views are now one vertical fader: scale, level, marks and controls on a single card. The Dials/Faders preference is gone.
- Calibration gains Felt, Pleasurable and Painful marks beside your calibrated maximum, kept per firmware, mode, channel and power level.
- Drag the maximum and every threshold on the fader, or set them in the Calibrate workbench by keyboard or screen reader.
- Copy calibration between channels.
- With a safety stop latched, the channel readout shows only levels the device has reported.
- A connection lost during a safety stop is stated plainly, with no Resume offered that cannot work.
- Safety stops are announced with their reason, and focus stays where you left it when a button becomes unavailable.
- Unreadable settings are left alone rather than overwritten, and the output limit is withheld rather than defaulting to a permissive one until they can be read.
Version 1.0.2
AlphaSecond alpha update.
- Firmware 2.127B is supported, including its battery reading.
- Phasonic drives output only on firmware that has been tested with it on a real 2B, and declines to drive any other.
- Calibration: set a maximum for each firmware, mode, channel and power level. It takes the place of the limit, now called the default limit, wherever one is set.
- If Phasonic ever closes unexpectedly, output is stopped as it closes, and the next launch offers to report what happened.
- Send feedback from Settings, under About. It opens a form on phasonic.app in your browser; Phasonic itself still sends nothing.
Version 1.0.1
AlphaFirst alpha update.
- Give each channel a label of your own.
- A battery indicator shows the 2B’s charge, tells battery from mains power, and warns when the battery is low.
- A link to the privacy policy in Settings, under About.
- A pre-release build warns you before it expires, and once expired explains why it will not connect.
Version 1.0.0
AlphaFirst alpha.
- Phasonic finds the 2B over its Digital Link and reconnects on its own. There is no port to choose.
- Output starts at zero on every connection, a limit you set clamps live output, and Esc stops everything from anywhere in the app.
- An output-integrity watchdog stops output the moment the device stops matching what you asked for.
- Supports firmware 2.106 and 2.132B.
- Works entirely offline: no account, no cloud, and nothing leaves your computer.